The Coal Gun™ features the lowest cost of ownership of today's stoker boilers, along with:
- Highest solid fuel efficiency
- Lowest fuel cost
- The most advanced grate/feed mechanism (thermal controlled grate option)
- Available with UL Listing and/or ASME!
- Convenient operation
- Low stack temperatures
- Uses Pea or Buckwheat Anthracite Coal
The most popular use for the Coal Gun is for residential hydronic
heating. Nevertheless, the Coal Gun is also available for steam heating
applications and is well-suited for the production of process hot water
for car washes, egg processing, greenhouse heating, manufacturing, and
for heating motels, pools and retail stores.
The Coal Gun™ is manufactured in Pennsylvania and burns anthracite
coal. Although normally used in hydronic or steam boiler applications,
the Coal Gun can be adapted for use with forced hot air systems through
the use of a water to air heat exchanger. Our smallest model (S130)
will provide heat for an entire home including domestic hot water at
50% or less than the cost of conventional oil, gas or electric systems.
For applications beyond 3.3 million BTU's Coal Gun™ coal stokers may be
installed in tandem. For more information about the Coal Gun, as well
as a list of options, click here.
Click Here
for Alternate Heating Systems Coal Boiler Partners.
Coal Gun™ Coal Stoker Boiler Specifications*
| MODEL (boiler only) |
S130 |
S260 |
S500 |
S1000 |
S1500 |
| Width |
20" |
23" |
33" |
40" |
45" |
| Height |
23" |
27" |
34" |
41" |
48" |
| Length |
32" |
46" |
63" |
77" |
100" |
| Weight (lbs - approx.) |
400 |
680 |
1,250 |
2,500 |
3,500 |
| Assembled |
|
|
|
|
|
| Width |
22" |
26" |
34" |
40" |
45" |
| Height |
42" |
47" |
58" |
66" |
77" |
| Length |
48" |
62" |
82" |
102" |
118" |
| Weight (lbs - approx.) |
875 |
1,276 |
2,200 |
3,800 |
5,000 |
| Water Capacity (gal - approx) |
27 |
56 |
115 |
220 |
380 |
| BTU/Hr |
130,000 |
260,000 |
500,000 |
995,000 |
1,650,000 |
| Flue Size (NPT) |
5" |
6" |
8" |
10" |
12" |
| Return Tapping (NPT) |
1 1/2" |
(2) 1 1/2" |
(2) 2" |
(2) 2 1/2" |
(2) 2 1/2" |
| Supply Tapping (NPT) |
1 1/2" |
(1) 1 1/2" |
(1) 2" |
(2) 2 1/2" |
(2) 2 1/2" |
*Specifications and design subject to change without notice.
Heating Capacity Using Hot Water/Low Pressure (15 psi) Steam Application*
| Model |
BTU/Hr |
Area (sq. ft.) |
| S130 |
130,000 |
4,000 |
| S260 |
260,000 |
8,000 |
| S500 |
500,000 |
15,000 |
| S1000 |
1,000,000 |
30,000 |
| S1500 |
1,650,000 |
50,000 |
*Depending on building construction, use, and insulation
Gal/Hr Capability for Process Hot Water, Based on 100° Rise
| Model |
Hot Water Capacity (gal/hr) |
| S260 |
250 |
| S500 |
500 |
| S1000 |
1,000 |
| S1500 |
1,650 |
All Specifications shown are approximate.
Photos:
   
|